Assignment on Observations during EEG experiment

Abstract: This objective of this study is to measure the EEG of diverse individuals on distinctive circumstances. We measured the Alpha, Beta, Delta and Theta of 7 individuals while reading and after presentation of troublesome Horror Pictures. An electroencephalogram (EEG) is a test that catches electrical movement in your mind utilizing little, Niedermeyer E. and da Silva F.L. (2004).  Level metal circles (cathodes) joined to your scalp. Your mind cells convey by means of electrical motivations and are dynamic constantly, actually when you’re sleeping.

The EEG is utilized within the assessment of cerebrum issue. Most ordinarily it is utilized to demonstrate the sort and area of the action in the mind amid a seizure. It additionally is utilized to assess individuals who are having issues connected with mind capacity. These issues may incorporate perplexity, trance like state, tumors, long haul challenges with speculation or memory, or debilitating of particular parts of the body, (for example, shortcoming connected with a stroke) Mulholland, Thomas (2012).

Introduction: Electroencephalography (EEG) is the process to record the neuron activity in the brain.This is a spontaneous activity for short time period usually for 20 -30 minutes. Diagnostics for the most part includes neural motions that is seen in EEG signals. EEG is frequently used to diagnose epilepsy, which causes clear aberrances in EEG readings. It is moreover used to diagnose sleep issue, great lethargies, encephalopathies, and brain passing. EEG used to be a first-line method for finding for tumors, stroke and other focal cerebrum disorders,however this use has reduced with the methodology of high-determination anatomical imaging methods, for instance, MRI and CT. Despite limited spatial determination, EEG continues being a gainful contraption for examination and dissection, especially when millisecond-range transient determination (implausible with CT or MRI) is required. Here are few benefits of EEG-

A few different strategies to study mind capacity exist, including utilitarian attractive reverberation imaging (fmri), positron discharge tomography, magnetoencephalography (MEG), Nuclear attractive reverberation spectroscopy, Electrocorticography, Single-photon outflow figured tomography, Near-infrared spectroscopy (NIRS), and Event-related optical sign (EROS). Regardless of the generally poor spatial affectability of EEG, it has various preferences over some of these procedures:

Fittings expenses are essentially lower than those of most different methods

EEG sensors can be utilized as a part of a greater number of spots than fmri, SPECT, PET, MRS, or MEG, as these methods require cumbersome and stable supplies. Case in point, MEG obliges gear comprising of fluid helium-cooled indicators that can be utilized just within attractively protected rooms, out and out costing upwards of a few million dollars and fmri obliges the utilization of a 1-ton magnet in, once more, a protected room.

EEG has high worldly determination, on the request of milliseconds instead of seconds. EEG is generally recorded at testing rates somewhere around 250 and 2000 Hz in clinical and examination settings, however cutting edge EEG information accumulation frameworks are fit for recording at inspecting rates over 20,000 Hz if wanted. MEG and EROS are the main  other non-invasive cognitive neuroscience methods that obtain information at this level of fleeting determination.

EEG is moderately tolerant of subject development, not at all like most other neuroimaging procedures. There even exist routines for minimizing, and actually dispensing with development ancient rarities in EEG information

EEG is noiseless, which considers better investigation of the reactions to sound-related jolts.

EEG does not irritate claustrophobia, not at all like fmri, PET, MRS, SPECT, and off and on again MEG

EEG does not include presentation to high-power (>1 Tesla) attractive fields, as in a percentage of alternate procedures, particularly MRI and MRS. These can result in a Innis, mixed bag of undesirable issues with the information, furthermore preclude utilization of these strategies with members that have metal embeds in their body, for example, metal-containing pacemakers .EEG does not include introduction to radioligands, dissimilar to positron emanation tomography. ERP studies can be led with moderately straightforward ideal models, contrasted and IE piece outline fmri studies .To a great degree uninvasive, dissimilar to Electrocorticography, which really obliges terminals to be put on the surface of the mind. EEG likewise has a few qualities that contrast positively Birbaumer, Niels (2003) and behavioral testing:

EEG can locate undercover handling (i.e., preparing that does not oblige a response)

EEG can be utilized as a part of subjects who are unequipped for making an engine reaction

Some ERP segments can be caught actually when the subject is not going to the boosts

Dissimilar to different method for concentrating on response time, Erps can illustrate phases of handling (as opposed to simply the last finished result).

EEG is an influential device for following mind progressions amid distinctive periods of life. EEG rest dissection can show noteworthy parts of the timing of mind health, including assessing juvenile cerebrum development. Mind action can likewise be observed by ct’s.

In EEG there is a superior understanding of what sign is measured as contrasted with other exploration procedures, i.e. the BOLD reaction in MRI.

Experimental aims and hypotheses: In this assignment, we have observed the EEG reports of 7 different persons at different circumstances. This can be observed by evaluating alpha,beta,delta and theta of 7 different persons. The aim of this assignment is to determine the reasons of neuronal excitability in the medial septal division. With the help of EEG test it is easy to determine the excitabily of neurons through alpha,beta,delta and theta.

 _

Alpha waves

Beta waves

  Theta waves

Delta waves

Mu waves

(All from Sept 1996 Issue of Scientific American: www.sciam.com/1096issue/1096lustedbox2.html)

Methods: The methodology adopted in this assignment involves comparison amount the available graph of EEG followed by normal reading and reading after disruption. They have compared 7 different persons. The activity was scheduled for one week. Following points were involved while taking EEG-

1. No Activity for 1 Min-Readings are observed among the entire 7 person when there is not activity for 1 minute.

2. Reading for 1 Min-Readings are taken after 1 minute of all the 7 persons.

3. During Disruption-After getting disruption, changes in the neural activity is observed among these 7 persons.

4. Reading After Disruption-Similarly, reading after disruption is observed.

This graph shows the variance of brain activity between 7 people

EEG observations-This is defined in terms of rhythmic activity and transients. These rhythmic activities are divided into bands by frequency. Here are results of different wave patterns-

1.Delta waves-This is the wave in which frequency is marked upto 4Hz.Sudden increase in delta waves are observed in the reading for 1 min and after disruption. This indicates that neurons of the brain increases their activity.

2.Theta waves-These waves are observed to increase  after disruption through horror activity. This is observed due to focal sub cortical lesions.

3.Alpha waves-Alpha reading remains stable in all the four readings. This involves activity in contra lateral sensory and motor cortical areas.

4.Beta waves slightly rises up when disruption is introduced.

Results: Observed results after comparative analysis is as follows–

    General observations in different modes    
Bands No Activity for 1 Min Reading for 1 Min During Disruption Reading After Disruption
Delta Normal Subcortical lesions metabolic encephalopathy hydrocephalus deep midline lesions
Theta Drowsiness focal subcortical lesions metabolic encephalopathy deep midline disorders
Alpha relaxed/reflecting Also associated with inhibition control, seemingly with the purpose of timing inhibitory activity in different locations across the brain. coma posterior regions of head, both sides, higher in amplitude on non-dominant side.
Beta  symmetrical distribution, most evident frontally; low-amplitude waves active thinking, focus anxious benzodiazepines

Neural interfacing is right now utilized within the fields of prescription, non-intrusive treatment, music, diversions and as a fascinating new include gadget. It is presently most used in helping the impaired in different ways.

As beforehand talked about, neural inserts are constantly used to help the visually impaired and hard of hearing. EOG signs have been utilized to diagnose and train patients with Strabismus, which is a misalignment of the eyes, bringing about look bearing to stray. [lusted, Knapp 1996].

Neural interfacing is the main system for correspondence for some crippled individuals, especially those with neuromuscular issue and spinal wounds. Some individuals can just flicker or move the muscles of their appearances. These individuals can utilize EMG or EOG signs to choose letters or move essential protests on a machine screen. EEG flags likewise have a considerable measure of guarantee around there, yet their multifaceted nature makes them hard to use in this way and work is proceeding in these zones.

Result:

These tables show the average of the activity for 3 weeks.

No Activity for 1 Min person1 person2 person3 person4 person5 person6 person7
Alpha

2.430

1.473

1.753

1.640

1.753

1.193

1.223

Beta

7.300

2.927

3.837

4.453

3.467

2.463

3.277

Delta

6.754

2.373

4.130

3.130

4.687

1.907

2.577

Theta

3.967

1.757

2.650

2.087

2.727

1.360

1.587

Reading for 1 Min person1 person2 person3 person4 person5 person6 person7
Alpha

2.117

1.790

2.157

1.960

1.687

1.740

1.327

Beta

4.637

4.463

4.147

4.333

3.137

4.913

3.133

Delta

5.827

3.157

4.673

4.697

4.673

3.663

3.053

Theta

3.360

2.183

3.443

3.000

2.770

2.327

1.890

During Disruption person1 person2 person3 person4 person5 person6 person7
Alpha

3.927

2.327

2.657

2.030

2.133

1.743

1.333

Beta

8.423

5.260

5.100

4.470

3.813

4.580

3.007

Delta

22.577

5.703

16.507

5.207

6.753

4.023

3.020

Theta

8.703

3.293

5.417

2.920

3.660

2.327

1.910

Reading After Disruption person1 person2 person3 person4 person5 person6 person7
Alpha

2.853

1.973

1.830

1.893

1.920

1.810

1.350

Beta

6.903

6.327

3.570

4.050

3.250

5.083

3.397

Delta

11.113

3.133

4.053

4.313

6.207

3.687

2.910

Theta

5.190

2.233

2.767

2.783

3.483

2.283

1.833

Discussion/Future Directions and Conclusions: Irregular action can comprehensively be differentiated into epileptiform and non-epileptiform movement. It can likewise be divided into central or diffuse. Central epileptiform releases speak to quick, Nuwer, Marc R. (1999) synchronous possibilities in an extensive number of neurons in a to some degree discrete territory of the cerebrum. These can happen as interictal  Schenck, John F. (1996) movement, in the middle of seizures, and speak to a region of cortical peevishness that may be inclined to creating epileptic seizures. Interictal releases are not completely solid for figuring out if a patient has epilepsy nor where his/her seizure may start. (See central epilepsy.) Summed up epileptiform releases frequently have a foremost most extreme, yet these are seen synchronously all through the whole mind. They are firmly suggestive of a summed up epilepsy. Central non-epileptiform unusual movement may happen over zones of the mind where there is central harm of the cortex or white matter. It frequently Brunberg, James A. (1997) comprises Logothetis, Nikos K. (2009) of an increment in moderate recurrence rhythms and/or a loss of typical higher recurrence rhythms. It might likewise show up as central or one-sided lessening in plentifulness of the EEG signal. Diffuse non-epileptiform unusual action may show as diffuse anomalous moderate rhythms or two-sided moderating of typical rhythms, for example, the PBR. Intracortical Encephalogram terminals and sub-dural cathodes can be utilized as a part of coupled to segregate and discretize Thorne, B. M. ( October 2006) antiquity from epileptiform and other extreme neurological occasions. More progressive measures of irregular EEG signs have likewise as of late got consideration as would be prudent biomarkers for diverse issue, for example, Alzheimer’s sickness.

Discussion: A routine clinical EEG recording ordinarily keeps going 20–30 minutes (in addition to arrangement time) and generally includes recording from scalp terminals. Routine EEG is commonly utilized within the accompanying clinical circumstances: to recognize epileptic seizures from different sorts of spells, for example, psychogenic non-epileptic seizures, syncope (swooning), sub-cortical development issue and headache variations. to separate “natural” encephalopathy or daze from essential psychiatric disorders, for example, mental shock -to serve as an aide test of mind demise to foresee, in specific occasions, in patients with trance like state to figure out if to wean against epileptic drugs .

Now and again, a routine EEG is not sufficient, especially when it is important to record a patient while he/she is having a seizure. For this situation, the patient Marnane, W (2010) may be admitted to the clinic for quite a long time or even weeks, while EEG is continually being recorded (alongside time-synchronized feature and sound recording). A recording of a real seizure (i.e., an ictal recording, instead of a between ictal recording of a conceivably epileptic patient at some period between seizures) can give fundamentally better data about whether a spell is Lounasmaa, Olli V. (1993) an epileptic seizure and the center in the cerebrum from which the seizure movement radiates.

Epilepsy checking is ordinarily done to recognize epileptic seizures from different sorts of spells, for example, psychogenic non-epileptic seizures, syncope (blacking out), sub-cortical development issue and Tatum, W. O., Husain, A. M., Benbadis, S. R. (2008) headache variations.

  • to portray seizures for the reasons of treatment
  • to limit the locale of mind from which a seizure begins Nunez PL, Srinivasan R (1981) for work-up of conceivable seizure surgery

Also, EEG may be utilized to screen certain systems:

  • to screen the profundity of anesthesia
  • as a circuitous pointer of cerebral perfusion in carotid endarterectomy
  • to screen amobarbital impact amid the Wada test

EEG can likewise be utilized within escalated tend to mind capacity observing:

  • to screen for non-convulsive seizures/non-convulsive status epilepticus
  • to screen the impact of narcotic/anesthesia Millet, David (2002) in patients in medicinally actuated extreme lethargies (for treatment of stubborn seizures or expanded intracranial weight) to screen for auxiliary mind harm in conditions, for example, subarachnoid discharge (at present an exploration technique).

On the off chance that a patient with epilepsy is continuously considered for resective surgery, it is regularly important to limit the center (source) of the epileptic cerebrum  Haas, L F (2003).  action with a determination more prominent than what is given by scalp EEG. This is on Pravdich-Neminsky, VV. (1913). the grounds that the cerebrospinal liquid, skull and scalp spread the electrical possibilities recorded by scalp EEG. In these cases, neurosurgeons normally embed strips and lattices of anodes (or entering profundity terminals) under the dura mater, through either a craniotomy or a burr gap. Feelings perceived from Electroencephalogram (EEG) could reflect the genuine “inward” emotions of the human. As of late, research on constant feeling distinguishment got more consideration since it could be connected in amusements, e-learning frameworks or even in promoting. EEG sign can be isolated into the delta, theta, alpha, beta, and gamma waves focused around their recurrence groups. In light of the Valence-Arousal-Dominance feeling model, we proposed a subject-subordinate calculation utilizing the beta/alpha proportion to perceive high and low strength levels of feelings from EEG. Three tests were composed and did to gather the EEG information marked with feelings. Sound cuts from International Affective Digitized Sounds (IADS) database and music pieces were utilized to summon feelings in the trials. Our methodology would permit constant distinguishment of the feelings characterized with diverse predominance levels in Valence-Arousal-Dominance model.

References:

  1. J. A. Russell, “Affective space is bipolar,” Journal of Personality and Social Psychology, vol. 37, pp. 345-356, 1979.
  2. A. Mehrabian, “Framework for a comprehensive description and measurement of emotional states,” Genetic, social, and general psychology monographs, vol. 121, pp. 339-361, 1995.
  3. A. Mehrabian, “Pleasure-Arousal-Dominance: A general framework for describing and measuring individual differences in temperament,” Current Psychology, vol. 14, pp. 261-292, 1996.
  4. D. O. Bos. 2006, EEG-based Emotion Recognition. Available: http://hmi.ewi.utwente.nl/verslagen/capita-selecta/CS-Oude-Bos-Danny.pdf.
  5. Q. Zhang and M. Lee, “Analysis of positive and negative emotions in natural scene using brain activity and GIST,” Neurocomputing, vol. 72, pp. 1302-1306, 2009.
  6. G. Chanel, J. J. M. Kierkels, M. Soleymani, and T. Pun, “Short-term emotion assessment in a recall paradigm,” International Journal of Human Computer Studies, vol. 67, pp. 607-627, 2009.
  7. Y. Liu, O. Sourina, and M. K. Nguyen, “Real-Time EEG-based Human Emotion Recognition and Visualization,” In Proc. 2010 Int. Conf. on Cyberworlds, Singapore, pp. 262-269, 2010.
  8. Y. Liu, O. Sourina, and M. K. Nguyen, “Real-Time EEG-Based Emotion Recognition and Its Applications,” Transactions on Computational Science XII, Lecture Notes in Computer Science, vol. 6670, pp. 256-277, 2011.
  9. Y. P. Lin, C. H. Wang, T. L. Wu, S. K. Jeng, and J. H. Chen, “EEG-based emotion recognition in music listening: A comparison of schemes for multiclass support vector machine,” in ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing – Proceedings, Taipei, 2009, pp. 489-492.
  10. K. Takahashi, “Remarks on emotion recognition from multi-modal bio-potential signals,” in Industrial Technology, 2004. IEEE ICIT ’04., pp. 1138-1143 Vol. 3. 2004.
  11. M. M. Bradley and P. J. Lang, “The International Affective Digitized Sounds (2nd Edition; IADS-2): Affective ratings of sounds and instruction manual,” University of Florida, Gainesville2007.
  12. P. J. Lang, M. M. Bradley, and B. N. Cuthbert, “International affective picture system (IAPS): digitized photographs, instruction manual and affective ratings,” University of Florida, Gainesville, 2005.
  13. R. Plutchik, Emotions and life : perspectives from psychology, biology, and evolution, 1st ed. Washington, DC: American Psychological Association, 2003.
  14. I. B. Mauss and M. D. Robinson, “Measures of emotion: A review,” Cognition and Emotion, vol. 23, pp. 209-237, 2009.
  15. P. D. Bolls, A. Lang, and R. F. Potter, “The effects of message valence and listener arousal on attention, memory, and facial muscular responses to radio advertisements,” Communication Research, vol. 28, pp. 627-651, 2001.
  16. S. Sanei and J. Chambers, EEG signal processing. Chichester, England ; Hoboken, NJ: John Wiley & Sons, 2007.
  17. D. Sammler, M. Grigutsch, T. Fritz, and S. Koelsch, “Music and emotion: Electrophysiological correlates of the processing of pleasant and unpleasant music,” Psychophysiology, vol. 44, pp. 293-304, 2007.
  18. N. Cristianini and J. Shawe-Taylor, An introduction to Support Vector Machines : and other kernel-based learning methods. New York: Cambridge University Press, 2000.
  19. Emotiv. Available: http://www.emotiv.com.
  20. M. M. Bradley, “Measuring emotion: The self-assessment manikin and the semantic differential,” Journal of Behavior Therapy and Experimental Psychiatry, vol. 25, pp. 49-59, 1994.
  21. A. V. Oppenheim and R. W. Schafer, Digital signal processing. Englewood Cliffs, N.J.: Prentice-Hall, 1975.
  22. C.-C. Chang and C.-J. Lin. LIBSVM : a library for support vector machines, 2001 [Online]. Available: http://www.csie.ntu.edu.tw/~cjlin/libsvm.
  23. P. C. Petrantonakis and L. J. Hadjileontiadis, “Emotion recognition from EEG using higher order crossings,” IEEE Transactions on Information Technology in Biomedicine, vol. 14, pp. 186-197, 2010.
  24. O. Sourina, Y. Liu, and M. K. Nguyen, “Real-time EEG-based Emotion Recognition for Music Therapy,” Journal on Multimodal User Interfaces, Springer-Verlag, Vol. 4, pp.27-35, 2011.
  25. O. Sourina, Y. Liu, Q. Wang, and M. K. Nguyen, “EEG-based Personalized Digital Experience,” Universal Access in HCI, Part II, HCII 2011, LNCS 6766, pp. 591–599. Springer, Heidelberg , 2011.
  26. O. Sourina, Y. Liu, and M. K. Nguyen, “Emotion-enabled EEG-based interaction,” in SIGGRAPH Asia 2011 Posters, SA’11 , art. no. 10 2011.
  27. IDM-Project (2008) Emotion-based personalized digital media experience in co-spaces. http://www3.ntu.edu.sg/home/eosourina/CHCILab/projects.html